BioTouch® 500 Specifications
Dimensions:
Length – 96mm, Height –31mm,
Width – 60mm, Weight – 150 grams
Image Capture Field of View:
20 × 25 mm
Image Format:
Standard – 500 ppi
BTO-200 compatibility – 340 ppi
Raw – 1000 ppi
Frame Rate:
6 frames per second at 500-ppi
Grayscale:
8-bit, 256 levels
Geometric Distortion:
1.5%
Operating Temperature:
0 to 55° Celsius (32 to 131° F) .
Relative Humidity:
0-90% non-condensing
ESD Immunity:
8kV contact; 16kV air discharge, without damage
Interface:
USB2. Connects directly to PC/laptop or self powered hub. 6’ cable with type A male connector.
Software:
BioEngine® software compatible.
Power:
Voltage – DC 4.4 to 5.25V from USB port
Power Consumption (at 5.0 volts) – 1.12W with LEDs on; 120mW in standby
Other:
FCC, CE and PIV compliance
Warranty:
90-day spare-in-the-air program.